Safety technical specification of phosphorus remover B
Part 1 Chemical name
Part 2 Composition / composition information
Part 3 Hazard overview
Part 4 First aid measures
Part 5 Fire fighting measures
Part 6 Leakage, emergency treatment
Part 7 Handling and storage
Part 8 Exposure control / personal protection
Part 9 Physical and chemical properties
Part 10 Stability and reactivity
Part 11 toxicological data
Part 12 Ecological data
Part 13 waste disposal
Part 14 transportation information
Part 15 regulatory information
Part 16 other information
Part 1 Chemical name
Chinese name of chemical: phosphorus remover B
Part 2 Composition / composition information
Harmful component: oxide
Content: ≥ 99.0%
Part 3 hazard overview
Hazard category: no data
Invasion route:/
Health hazard: phosphorus remover B stimulates mucous membrane and causes conjunctivitis and rhinitis. The smoke concentration of phosphorus remover B inhaled by human is 4-6mg / m3, which can be released after 1 or 2 minutes
Metal smoke fever, fever, cough, chest compression, leukocyte increase significantly, but the symptoms are lighter and less than those caused by zinc oxide smoke
See you. It is reported that oral administration of a large amount of phosphorus remover B can cause fever reaction, leukocytosis and so on.
Environmental hazards: no data
Fire and explosion hazard: no data
Part 4 first aid measures
Skin contact: take off contaminated clothes and rinse with flowing water.
Eye contact: lift the eyelids and rinse with flowing water or normal saline. See a doctor.
Inhalation: quickly leave the site to a place with fresh air. If breathing is difficult, give oxygen. See a doctor.
Ingestion: drink enough warm water to induce vomiting. See a doctor.
Part 5 fire fighting measures
Hazard characteristics: when mixed with halides such as phosphorus pentachloride, violent chemical reaction can occur.
Harmful combustion products: natural decomposition products are unknown.
Fire extinguishing method: Firefighters must wear full body fire and poison proof clothes and extinguish the fire in the upwind direction. When extinguishing the fire, move the container from the fire site to an open place as far as possible.
Emergency treatment: isolate the leakage contaminated area and restrict access. It is recommended that emergency treatment personnel wear dust masks (full face masks) and gas suits. Avoid raising dust,
Carefully sweep it up, place it in a bag and transfer it to a safe place. If there is a large amount of leakage, cover it with plastic cloth and canvas. Collect, recycle or transport to waste disposal site
management.
Part 7 handling and storage
Precautions for operation: close operation and pay attention to ventilation. Operators must receive special training and strictly abide by the operating procedures. Operators are advised to wear
Wear self-priming filter dust mask, chemical safety protective glasses, anti poison penetration work clothes and rubber gloves. Avoid dust generation. avoid
Contact with oxidants, acids and halides. Handle with care to prevent package damage. Equipped with leakage emergency treatment equipment. Empty containers can
Harmful substances can remain.
Storage precautions: store in a cool and ventilated warehouse. Keep away from kindling and heat sources. It should be stored separately from oxidants, acids and halides
Mixed storage. The storage area shall be equipped with appropriate materials to contain leakage.
Part 8 exposure control / personal protection
China MAC (mg / m3): no standard
Monitoring method:/
Engineering control: closed operation, pay attention to ventilation.
Respiratory protection: when the dust concentration in the air exceeds the standard, you must wear a self-priming filter dust mask. In case of emergency rescue or evacuation
Wear an air respirator.
Eye protection: wear chemical safety glasses.
Diced bean
Body protection: wear anti poison penetration work clothes.
Hand protection: wear rubber gloves.
Part 9 physical and chemical characteristics
Appearance and properties: white powder
PH: / melting point (° C): 2800
Relative density (water = 1): 3.58
Boiling point (c): 3600
Relative vapor density (air = 1): no data
Molecular formula: MgO
Molecular weight: 40.31
Main ingredients: pure
Saturated vapor pressure (kPa): no data available
Heat of combustion (kJ / mol): meaningless
Critical temperature (c): meaningless
Critical pressure (MPA): meaningless
Logarithm of octanol / water partition coefficient: no data
Flash point (c): meaningless
Explosion Upper limit% (VV): meaningless
Ignition temperature (c): meaningless
Lower explosive limit% (V / V): meaningless
Solubility: slightly soluble in water.
Main uses: used as antacid and laxative.
Other physical and chemical properties:/
Part 10 stability and reactivity
Stability: 1
Strong oxidizing agent and strong halide.
Conditions to avoid contact: 1
Polymerization hazard: 1
Decomposition products: 1
Acute toxicity: LD50: no data
LC50: no data
Subacute and chronic toxicity: 1
Irritation:/
Sensitization:/
Mutagenicity:/
Teratogenicity:/
Carcinogenicity:/
Part 12 ecological data
Ecotoxicological toxicity: 1
Biodegradability: 1
Non biodegradability:/
Bioaccumulation or bioaccumulation:/
Other harmful effects:/
Part 13 disposal
Nature of waste: no data
Waste disposal method: use safe burial method for disposal.
Precautions for abandonment: no data
Part 14 transportation information
Dangerous goods No.: no data
UN No.: no data
Packing mark: no data
Packing category: z01
Packing method: no data
Precautions for transportation: the package shall be complete and the loading shall be stable at the time of shipment. During transportation, ensure that the container does not leak, collapse, fall or damage
Bad. It is strictly prohibited to load and transport with oxidants, acids, halides, edible chemicals, etc. During transportation, it shall be protected from sun exposure, rain and high temperature. Vehicle transportation
Clean thoroughly after transportation.
Part 15 regulatory information
Regulations of the State Council on the administration of hazardous substances (March 15, 2002)
Detailed rules (HLF [1992] No. 677), regulations on the safe use of chemicals in the workplace ([1996] LBF No. 423) and other regulations for chemical hazards
Relevant provisions have been made on the safe use, production, storage, transportation, loading and unloading of products; Hygienic standard for phosphorus removal agent B (smoke) in the air of workplace (GB
16195-1996), which specifies the maximum allowable concentration and detection method of the substance in the air of the workshop.